| PLC |  | 
 
Easy Programming
	- You can program and modify directly on the LCD by pressing the button, so you needn't any other special tools and connection.
- Free software of programming and monitoring - QUICK II and FAB-scanda.
Analog inputs receivable
With the help of our FAB, analog inputs can be easily received. Either a long distance monitoring or status of RTC execution on PC or to edit, after program and parameter printing by MODEM simply with special connector.
127 - set RTC Control
Big capable 127-set of function-block or ladder programs, are specially designed for time control.
Initiative Separated Panel with LCD display
One LCD display plate is able to match w/multi FAB units for cost saving.
Telephone connectable and voice warning
Monitoring through telephone digit or MODEM by the pre-set programs after your required commands, even to program voice warning function available.
   
    
              
                | 
       
       Application Scope 
  
    | 
        	Automatic Door controlDispose of sewage automationLighting AutomationStreet lamp automation controlAgriculture irrigation & lighting controlHome workTunnel automatic light adjustment control	Anti-burglary security system | 
        	Fountain control systemIntercity automationNeon street light controlIntelligent residence controlIndustrial automationFactory school bell automation controlMachinery tool automation |  | 
        
     
      
      
              
                | 
       General Technical Characteristics 
              
                | Certificate | : | CE |  
              |  |  
                | Program size | : | 127 Blocks |  
              |  |  
                | LCD display | : | 4 lines of characters |  
              |  |  
                | Timer | : | 127 |  
              |  |  
                | Storage | : | -40°C~+70°C |  
              |  |  
                | Programming Method | : | FBD |  
              |  |  
                | Program Memory | : | 64 K |  
              |  |  
                | Counter | : | 127 |  
              |  |  
                | RTC | : | 127 |  
              |  |  
                | Operating temperature | : | -5°C~+55°C |  Fab Parts 
              
                | AF-LCD | : | LCD Panel |  
              |  |  
                | AFCAP | : | Common Cover |  
              |  |  
                | AF-C232 | : | Interface between FAB and Modem or pc |  
              |  |  
                | AF-C485 | : | Voice function module |  
              |  |  
                | AF-P485 | : | Interface between computer and 485bus |  
              |  |  
                | AF-MUL | : | Voice function module |  
              |  |  
                | AF-M232 | : | Interface between FAB and Modem |  
              |  |  
                | QUICKII/FAB/ SCANDA | : | FAB programming and monitoring software |  
              |  |  | 
        
        
        Specification
               
    	
              
                | 
     
											  
											    
											      | No | Model | Power Supply | Input | Output |  
											      | 1 | AF-10MR-A | AC100~240V | 6-Point AC Input | 4-Point Relay Output |  
											      | 2 | AF-10MR-E | AC/DC12~24V | 6-Point AC/DC Input | 4-Point Relay Output |  
											      | 3 | AF-10MT-E | DC 12~24V | 6-Point DC Input | 4-Point Transistor Output |  
											      | 4 | AF-10MR-D | DC 12~24V | 6-Point DC(Analog) Input | 4-Point Relay Output |  
											      | 5 | AF-10MT-D | DC 12~24V | 6-Point DC(Analog) Input | 4-Point Transistor Output |  
											      | 6 | AF-20MR-A | AC100~240V | 12-Point AC Input | 8-Point Relay Output |  
											      | 7 | AF-20MR-E | AC/DC12~24V | 12-Point AC/DC Input | 8-Point Relay Output |  
											      | 8 | AF-20MT-E | DC 12~24V | 12-Point DC Input | 8-Point Transistor Output |  
											      | 9 | AF-20MR-D | DC 12~24V | 12-Point DC(Analog) Input | 8-Point Relay Output |  
											      | 10 | AF-20MT-D | DC 12~24V | 12-Point DC(Analog) Input | 8-Point Transistor Output |  
											      | 11 | AF-LCD | Removable LCD for programming |  
											      | 12 | AF-CAP | Common cover for representing the LCD panel |  
											      | 13 | AF-C232 | Interface between FAB, MODEM & PC |  
											      | 14 | AF-C485 | Interface between FAB 
											        & RS 485 bus for networking & monitoring |  
											      | 15 | AF-P485 | Interface between COM port of PC & RS 485
											        bus for networking |  
											      | 16 | AF-MUL | Phone voice block for recording & broadcasting
											        (AC power) |  
											      | 17 | AF-M232 | Interface between AF-C232 
											        & MODEM for communication |  
											      | 18 | CD-ROM | FAB software (including QUICK II & SCADA
											        3.0) |  
											      | 19 | AF-COPY | Copy module |  
											      | 20 | AF-MUL-D | Phone voice block for recording & broadcasting (DC
											        power) |  
											      | 21 | AF-CMP | The connecting cable between To PC connection of the telephone
											        voice module and PC |  |